Roof Type - Combination: standing seam metal panel & TPO-membrane
Security - Fully-fenced site with shared buildings with guard shack-controlled access
Loading Type - Rear / Side Loading
Construction Type - Varies: Steel columns and girders supporting open-web steel roof. Structural tile-up, precast concrete & insulated metal panels
Fire Sprinklers - Wet-Pipe
HVAC - Building cooled by rooftop-mounted packaged units, as well as split-systems with roof-mounted condensing units. The HVAC units provide heat via natural gas. The refrigerated warehouse is cooled by four (4) ammonia compressors and a series of evaporators which are ceiling-hung in the coolers and freezers.